Facebook pixel tracking

The Science and Information (SAI) Organization publishes open-access peer-reviewed journals in computer science and artificial intelligence.

Contact Info
Website thesai.org
Follow Us
Contact Info
Follow Us
Research Article | Open Access |

Accuracy and Reliability of Monocular 3D Pose Estimation for Lower-Limb Movement Analysis

Author 1: Guangjun Wang Author 2: Jiaojiao Chen Author 3: Mengxia Hu Author 4: Cezhong Luo Author 5: Kaibo Li Author 6: Xiaohui Chen
International Journal of Advanced Computer Science and Applications (IJACSA) · Vol. 17, No. 10 · Published 2026

DOI: 10.14569/IJACSA.2026.0171065

Abstract

Optical motion capture provides accurate joint kinematics, but its cost and setup complexity limit routine use in rehabilitation and home monitoring. Monocular RGB video is a low-cost alternative, yet many 3D pose estimation studies report overall errors on public benchmarks without distinguishing lower-limb movements or individual joints. This study evaluated the spatial and frame-to-frame displacement errors of a two-stage pipeline combining BlazePose 2D detection with a dilated temporal convolutional network for 3D lifting. We constructed a paired dataset of monocular RGB video and optical motion capture from 10 healthy participants performing six standardized lower-limb movements, yielding 450 samples and approximately 202,500 frames. Under the within-participant recording-set evaluation, the fine-tuned pipeline achieved an MPJPE of 32.03 mm, compared with 121.70 mm for direct BlazePose 3D output. Errors varied across movements, from 11.21 mm for quiet standing to 62.83 mm for seated knee extension, with distinct patterns at the hip, knee, and ankle. At a noise standard deviation of 5.4 pixels, independent Gaussian perturbations of 2D keypoints increased MPJPE by approximately 0.9% but increased mean per-joint velocity error (MPJVE), measured here as frame-to-frame displacement error, by about 234%. Selected joint-angle measurements also showed movement-dependent agreement with optical motion capture. These findings provide movement- and joint-specific evidence on position accuracy, temporal sensitivity, and selected kinematic agreement under controlled laboratory conditions.

Keywords

How to Cite this Article

Wang, G., Chen, J., Hu, M., Luo, C., Li, K., & Chen, X. (2026). Accuracy and Reliability of Monocular 3D Pose Estimation for Lower-Limb Movement Analysis. International Journal of Advanced Computer Science and Applications, 17(10). https://doi.org/10.14569/IJACSA.2026.0171065

Wang, Guangjun, et al.. "Accuracy and Reliability of Monocular 3D Pose Estimation for Lower-Limb Movement Analysis." International Journal of Advanced Computer Science and Applications, vol. 17, no. 10, 2026, https://doi.org/10.14569/IJACSA.2026.0171065.

@article{Wang2026,
  title     = {Accuracy and Reliability of Monocular 3D Pose Estimation for Lower-Limb Movement Analysis},
  journal   = {International Journal of Advanced Computer Science and Applications},
  volume    = {17},
  number    = {10},
  year      = {2026},
  publisher = {The Science and Information Organization},
  author    = {Guangjun Wang and Jiaojiao Chen and Mengxia Hu and Cezhong Luo and Kaibo Li and Xiaohui Chen},
  doi       = {10.14569/IJACSA.2026.0171065},
  url       = {https://doi.org/10.14569/IJACSA.2026.0171065}
}

Open Access — licensed under a Creative Commons Attribution 4.0 International License. Unrestricted use, distribution, and reproduction in any medium, even commercially, as long as the original work is properly cited.

Call for Papers - Important Dates

Volume 17 No. 12, December 2026
Paper Submission Due November 25, 2026
Review Notification December 15, 2026
Publication Date December 31, 2026